6ft UK Computer Power Cord, BS1363 to IEC C13, 18 AWG H05VV-F, 10A/250V, 13A Fused, Black

SKU: PW109-1206

In stock

Volume pricing
Qty
Price
1
$3.76
2
$3.70
20
$3.62
40
$3.47
$3.76
Order today, shipped within 24 hours
Delivery method: USPS Ground Advantage® Shipping time: 2-5 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: USPS Priority Mail® Shipping time: 1-3 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: UPS Ground Shipping time: 1-5 Business Days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam) except P.O. Box
Delivery method: UPS 3 Day Select Shipping time: 3 Business Days Guarantee Service Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS 2nd Days Air Shipping time: 2 Business Days Guarantee Service Availability: All 50 U.S. states and Puerto Rico with some limitations in Alaska and Hawaii except P.O.Box
Delivery method: UPS Next Day Air Shipping time: Next Business Day Guarantee, normally by 10:30am depending on " SHIP-TO ZIP CODE" Availability: All U.S. states (including Alaska, Hawaii, Puerto Rico) except P.O.Box
Delivery method: UPS Next Day Air Saver Shipping time: Next Business Day Guarantee, normally by 3:30pm (business) and the end of the next business day (Residential) depending on "SHIP-TO ZIP CODE" Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS Next Day Air Early Shipping time: Next Business Day Guarantee, normally by 8:30am, depending on "SHIP-TO ZIP CODE" Availability: All 48 U.S. continguous states and Archorage, AK except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Orders received by 2:00 PM PST are generally processed on the same business day. Orders received after this cutoff time will be processed within 24 to 48 hours. Shipping times are determined by the chosen shipping method and destination address. For details, please visit our Shipping Policy Page.
quote

Read more about Add to Quote

By adding items to your Quote Cart, you can request a personalized quote tailored to your specific needs. This is especially useful for bulk orders, as we may be able to offer you special pricing based on the quantity. Once you've added products to your Quote Cart, simply submit your request, and our team will get back to you promptly with a detailed quote. We're here to ensure you get the best value and service for your purchase!
compare

Product Features

  • UK BS1363 (Type G) plug with 13A fuse: Molded BS 1363/A three-pin UK plug fitted with a replaceable 13A fuse to BS 1362 and BSI approved under licence KM 77531; plugs into any UK, Ireland, Hong Kong, Singapore, or Malaysia Type G wall socket, surge strip, or PDU.
  • 18 AWG H05VV-F copper cable rated 10A/250V: H05VV-F 3G 0.75 mm² (18 AWG) cordage with stranded non-CCA copper conductors carries 10 amps continuous at 250 volts AC, supporting up to 2,500 watts within the cable's rating while the C13 interface caps the connection at 10A.
  • IEC 60320 C13 device connector: Molded C13 receptacle mates with the universal C14 inlet found on PCs, monitors, printers, scanners, servers, network switches, UPS, and PDU equipment, so a single cord type powers most standard computing hardware from UK mains.
  • Internationally certified and RoHS compliant: Assembly carries BSI, ENEC, KEMA-KEUR, and VDE approvals and meets the RoHS directive, with a continuous protective earth from the plug's earth pin through the green/yellow conductor to the C13 ground contact.
  • Versatile Applications: Powers desktop computers, monitors, printers, scanners, PoE switches, rack servers, and UPS/PDU loads across offices, server rooms, data centers, AV racks, and labs throughout the UK and former British Overseas Territories.

Product Features

  • UK BS1363 (Type G) plug with 13A fuse: Molded BS 1363/A three-pin UK plug fitted with a replaceable 13A fuse to BS 1362 and BSI approved under licence KM 77531; plugs into any UK, Ireland, Hong Kong, Singapore, or Malaysia Type G wall socket, surge strip, or PDU.
  • 18 AWG H05VV-F copper cable rated 10A/250V: H05VV-F 3G 0.75 mm² (18 AWG) cordage with stranded non-CCA copper conductors carries 10 amps continuous at 250 volts AC, supporting up to 2,500 watts within the cable's rating while the C13 interface caps the connection at 10A.
  • IEC 60320 C13 device connector: Molded C13 receptacle mates with the universal C14 inlet found on PCs, monitors, printers, scanners, servers, network switches, UPS, and PDU equipment, so a single cord type powers most standard computing hardware from UK mains.
  • Internationally certified and RoHS compliant: Assembly carries BSI, ENEC, KEMA-KEUR, and VDE approvals and meets the RoHS directive, with a continuous protective earth from the plug's earth pin through the green/yellow conductor to the C13 ground contact.
  • Versatile Applications: Powers desktop computers, monitors, printers, scanners, PoE switches, rack servers, and UPS/PDU loads across offices, server rooms, data centers, AV racks, and labs throughout the UK and former British Overseas Territories.

Product Description

6ft UK Computer Power Cord, BS1363 to IEC C13, 18 AWG H05VV-F, 10A/250V, 13A Fused, Black

 

The CableLeader PW109-12XX is a UK BS 1363 (Type G) to IEC 60320 C13 power cord that connects computers, monitors, and other C14-inlet equipment to British mains outlets. One end terminates in a molded three-pin BS 1363 plug — the standard square-pin plug used across the United Kingdom and former British Overseas Territories — fitted with a 13A fuse for outlet-side protection. The opposite end carries a molded IEC 60320 C13 receptacle that mates with the C14 power inlet built into most desktop PCs, displays, printers, and rack hardware. Between the two connectors runs flexible H05VV-F three-conductor cordage in black PVC.

 

The BS 1363 plug is what sets this cord apart from a standard US computer power cord. Its rectangular earth, live, and neutral pins fit only Type G wall sockets, and the integrated 13A fuse satisfies UK wiring regulations that require fused plugs on flexible cords. The plug is BSI approved under licence KM 77531 and wired to British colour code — brown live, blue neutral, green/yellow earth — for a direct one-to-one connection through to the C13 outlet. Buyers in Ireland, Hong Kong, Singapore, Malaysia, and the UAE use the same Type G interface, so the cord serves the wider British-standard region rather than the UK alone.

 

The IEC 60320 C13 connector is the universal device end of the computer power cord family. It plugs into the C14 appliance inlet found on PC power supplies, professional monitors, laser printers, scanners, rack-mount servers, network switches, KVM units, and the outlets of many UPS and PDU systems. Because the C13/C14 interface is standardized worldwide, the only variable that changes between regions is the wall plug — here a UK Type G plug instead of a US NEMA, EU Schuko, or other national standard. This makes the cord a direct replacement for lost or damaged kettle-style computer leads on equipment already installed in UK facilities.

 

Electrical capacity is governed by the conductor and the connectors. The H05VV-F 0.75 mm² (18 AWG) cable uses stranded copper conductors rated 10 amps at 250 volts AC, matching the 10A ceiling of the C13 interface, while the BS 1363 plug carries a 13A fuse sized to British practice. The assembly holds BSI, ENEC, KEMA-KEUR, and VDE safety approvals and complies with the RoHS directive restricting lead, mercury, cadmium, hexavalent chromium, and brominated flame retardants. A continuous earth path runs from the plug's earth pin through the green/yellow conductor to the C13 ground contact, preserving protective earth for connected equipment.

 

Construction favors durability in reconfigured environments. Both connectors are PVC overmolded, locking the terminal connections and cable jacket into a single strain-relief body with no screws or exposed conductors, so the cord withstands repeated plug and unplug cycles in busy server rooms and under desks. The 6.8 mm black jacket coils neatly for routing through cable management arms, rack cabinets, and AV credenzas, and the molded fuse cover on the plug opens for fuse replacement without tools beyond a screwdriver. This combination suits both fixed installations and frequently moved equipment.

The black jacket provides a professional appearance and suits standard data center and enterprise rack deployments.

 

Compatibility & Ordering Information — PW109-12XX is compatible with any device or power source that uses a standards-compliant IEC 60320 C14 inlet, including PCs, monitors, printers, servers, switches, and the C13-output sockets on UK PDUs and UPS units from APC, Tripp Lite, Eaton, CyberPower, and Vertiv. It plugs into any UK Type G wall socket, extension lead, or surge strip. The cord is offered in multiple standard lengths to suit desktop drops, in-rack runs, and rack-to-wall routing; select the length variant that matches your layout. Custom lengths, bulk packaging, and OEM kitting are available on request — contact CableLeader for quotations or co-packaging programs.

 

 

Product Comparison: UK BS1363 to C13 vs US NEMA 5-15P to C13

Both cords end in the same IEC C13 device connector, so buyers often cross-shop them. The only difference that matters is the wall plug and its country. Use the table below to pick the correct one for your outlet.

AttributeUK BS1363 (Type G) to C13US NEMA 5-15P to C13
Wall PlugBS 1363 (Type G) UK square-pin plug with 13A fuseNEMA 5-15P US flat-blade 3-prong plug, no fuse
Device ConnectorIEC 60320 C13 (fits C14 inlet)IEC 60320 C13 (fits C14 inlet)
Region / VoltageUK, Ireland, Hong Kong, Singapore, Malaysia, UAE; 230–250VUnited States, Canada, Mexico; 120V
Plug Fuse13A BS 1362 fuse (required by UK wiring rules)None (fuse not used on US plugs)
Current Rating10A at 250V (C13 interface limit)10A at 125V (C13 interface limit)
CableH05VV-F 3G 0.75 mm² (18 AWG) copperSVT or SJT 18 AWG copper
Use This WhenEquipment is installed in a UK / British-standard facilityEquipment is installed in a North American facility

Choose the UK BS1363 to C13 cord when the device must plug into a British Type G wall socket.
Choose the US NEMA 5-15P to C13 cord when the device plugs into a North American 120V outlet. The C13 device end is identical on both — only the wall plug changes.

 

 

FAQ

Q1. What is the difference between a UK BS1363 to C13 cord and a US NEMA 5-15P to C13 cord?

Both cords share the same IEC C13 device end, but the wall plug differs by country. The UK BS1363 (Type G) version has a square-pin British plug with a 13A fuse and fits UK and former British Commonwealth sockets at 230–250V. The US NEMA 5-15P version has flat blades for 120V North American outlets and no fuse. They are not interchangeable — the plug must match the country's wall socket.

Q2. Which devices and countries can use this cord?

The C13 end fits any device with a standard C14 inlet — PCs, monitors, printers, scanners, servers, switches, UPS, and PDUs. The BS1363 (Type G) plug works in the United Kingdom, Ireland, Hong Kong, Singapore, Malaysia, the UAE, and other regions that use the British square-pin standard. Anywhere with Type G wall sockets, this cord powers C14-inlet equipment.

Q3. What is the current rating — 10A or 13A?

The cord is rated 10A at 250V, set by the C13 connector and the 18 AWG (0.75 mm²) conductor, which equals up to 2,500 watts. The BS1363 plug carries a 13A fuse because that is the standard British fuse size, but the safe continuous load is governed by the 10A C13 rating. Size connected equipment to 10A or less.

Q4. Which end plugs into the wall and which into the device?

The BS1363 (Type G) plug — the square three-pin end with the fuse — goes into the UK wall socket, extension lead, or PDU. The IEC C13 receptacle — the notched female connector — pushes onto the C14 inlet on the back of the computer, monitor, or other equipment. The cord is keyed and polarized, so each end fits only its matching socket.

Q5. Is this the same as a kettle lead, and which length should I choose?

This is commonly called a “kettle lead” in the UK, though a true kettle lead uses the higher-temperature C15 connector; this cord uses the standard C13 for computers and IT gear. Choose a shorter length for desktop and in-rack drops to reduce clutter, and a longer length for floor-box or rack-to-wall routing. Leave a small service loop so equipment can be moved without unplugging.

Technical Specifications

Name
6ft UK Computer Power Cord, BS1363 to IEC C13, 18 AWG H05VV-F, 10A/250V, 13A Fused, Black
SKU
PW109-1206
Color
Black
Gender
Male to Female
Connector
3-pin shroud Female (IEC-320-C13) to UK PLUG (BS1363)
Condition
New
RoHS Compliant
Yes
Country of Manufacture
Vietnam
Specification
  • Connector A: BS 1363 (Type G) UK plug, molded PVC, 3-pin, fitted with 13A BS 1362 fuse
  • Connector B: IEC 60320 C13 (female receptacle, molded PVC, 3-pin)
  • Conductor: 18 AWG (0.75 mm²) H05VV-F, stranded copper
  • Power Rating: 10A / 250V (cable and C13 end); BS1363 plug fitted with 13A fuse
  • Length: 6ft (1.83 m)
  • Color: Black
  • Certifications: VDE, ENEC, SAA, BSI
  • Compliance: RoHS directive
  • Country of Origin: Vietnam
Features
  • UK BS1363 (Type G) plug with 13A fuse: Molded BS 1363/A three-pin UK plug fitted with a replaceable 13A fuse to BS 1362 and BSI approved under licence KM 77531; plugs into any UK, Ireland, Hong Kong, Singapore, or Malaysia Type G wall socket, surge strip, or PDU.
  • 18 AWG H05VV-F copper cable rated 10A/250V: H05VV-F 3G 0.75 mm² (18 AWG) cordage with stranded non-CCA copper conductors carries 10 amps continuous at 250 volts AC, supporting up to 2,500 watts within the cable's rating while the C13 interface caps the connection at 10A.
  • IEC 60320 C13 device connector: Molded C13 receptacle mates with the universal C14 inlet found on PCs, monitors, printers, scanners, servers, network switches, UPS, and PDU equipment, so a single cord type powers most standard computing hardware from UK mains.
  • Internationally certified and RoHS compliant: Assembly carries BSI, ENEC, KEMA-KEUR, and VDE approvals and meets the RoHS directive, with a continuous protective earth from the plug's earth pin through the green/yellow conductor to the C13 ground contact.
  • Versatile Applications: Powers desktop computers, monitors, printers, scanners, PoE switches, rack servers, and UPS/PDU loads across offices, server rooms, data centers, AV racks, and labs throughout the UK and former British Overseas Territories.
Length
6 FT
Connector
BS1363 to C13
Cable Gauge
18 AWG
Power Rating
13 Amp / 250 Volt
Jacket Type
PVC

Frequently Asked Questions

No Questions
loader
0.0
0 Reviews
 / 
0 Questions
 / 
0 Answers
Reviews (
0
)
Questions (
0
)
loader
loader
loader