3ft IEC-60320 C14 to C19 Extension Power Cord 14AWG 15A/250V SJT, Black

SKU: PW128-1203

In stock

Volume pricing
Qty
Price
1
$5.03
2
$4.75
20
$4.49
40
$3.94
$5.03
Order today, shipped within 24 hours
Delivery method: USPS Ground Advantage® Shipping time: 2-5 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: USPS Priority Mail® Shipping time: 1-3 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: UPS Ground Shipping time: 1-5 Business Days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam) except P.O. Box
Delivery method: UPS 3 Day Select Shipping time: 3 Business Days Guarantee Service Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS 2nd Days Air Shipping time: 2 Business Days Guarantee Service Availability: All 50 U.S. states and Puerto Rico with some limitations in Alaska and Hawaii except P.O.Box
Delivery method: UPS Next Day Air Shipping time: Next Business Day Guarantee, normally by 10:30am depending on " SHIP-TO ZIP CODE" Availability: All U.S. states (including Alaska, Hawaii, Puerto Rico) except P.O.Box
Delivery method: UPS Next Day Air Saver Shipping time: Next Business Day Guarantee, normally by 3:30pm (business) and the end of the next business day (Residential) depending on "SHIP-TO ZIP CODE" Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS Next Day Air Early Shipping time: Next Business Day Guarantee, normally by 8:30am, depending on "SHIP-TO ZIP CODE" Availability: All 48 U.S. continguous states and Archorage, AK except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Orders received by 2:00 PM PST are generally processed on the same business day. Orders received after this cutoff time will be processed within 24 to 48 hours. Shipping times are determined by the chosen shipping method and destination address. For details, please visit our Shipping Policy Page.
quote

Read more about Add to Quote

By adding items to your Quote Cart, you can request a personalized quote tailored to your specific needs. This is especially useful for bulk orders, as we may be able to offer you special pricing based on the quantity. Once you've added products to your Quote Cart, simply submit your request, and our team will get back to you promptly with a detailed quote. We're here to ensure you get the best value and service for your purchase!
compare

Product Features

  • IEC 60320 C14 male plug feeds power from PDU C13 outlet: The C14 plug (MSL-106, UL E210037) on one end inserts into any IEC 60320 C13 outlet on a rack PDU, UPS bypass receptacle, or in-rack power strip, providing the source side of a controlled extension between rack power infrastructure and downstream high-current equipment.
  • 14 AWG SJT cable with pure stranded copper, non-CCA conductors: The 3-conductor jacketed SJT cable runs 2.08 mm² (14 AWG) pure copper — not copper-clad aluminum — supporting 15 amps continuous at 250 volts AC under the C14 source-side limit; the SJT jacket is rated VW-1 flame retardant at 105°C with a 300-volt wire-side ceiling that exceeds the connector interface by a comfortable margin.
  • IEC 60320 C19 female receptacle accepts any C20-inlet device: The C19 receptacle (MSL-119, UL E210037) on the opposite end accepts the C20 plug found on high-current 1U and 2U rack servers, blade chassis, enterprise core and aggregation network switches, KVM-over-IP appliances, and high-capacity UPS bypass cables, letting a 15A-rated PDU outlet supply a C20-equipped load through a single locked-down assembly.
  • Versatile PDU, Server, and Data Center Applications: Serves as a heavy-duty extension between any IEC 60320 C13 outlet on 0U/1U basic, metered, and switched rack PDUs or UPS bypass receptacles and any C20-inlet equipment in server cabinets, edge compute racks, network closets, lab benches running high-current test equipment, and industrial workshops powering bench instruments requiring 250-volt feed from a standard PDU outlet.

Product Features

  • IEC 60320 C14 male plug feeds power from PDU C13 outlet: The C14 plug (MSL-106, UL E210037) on one end inserts into any IEC 60320 C13 outlet on a rack PDU, UPS bypass receptacle, or in-rack power strip, providing the source side of a controlled extension between rack power infrastructure and downstream high-current equipment.
  • 14 AWG SJT cable with pure stranded copper, non-CCA conductors: The 3-conductor jacketed SJT cable runs 2.08 mm² (14 AWG) pure copper — not copper-clad aluminum — supporting 15 amps continuous at 250 volts AC under the C14 source-side limit; the SJT jacket is rated VW-1 flame retardant at 105°C with a 300-volt wire-side ceiling that exceeds the connector interface by a comfortable margin.
  • IEC 60320 C19 female receptacle accepts any C20-inlet device: The C19 receptacle (MSL-119, UL E210037) on the opposite end accepts the C20 plug found on high-current 1U and 2U rack servers, blade chassis, enterprise core and aggregation network switches, KVM-over-IP appliances, and high-capacity UPS bypass cables, letting a 15A-rated PDU outlet supply a C20-equipped load through a single locked-down assembly.
  • Versatile PDU, Server, and Data Center Applications: Serves as a heavy-duty extension between any IEC 60320 C13 outlet on 0U/1U basic, metered, and switched rack PDUs or UPS bypass receptacles and any C20-inlet equipment in server cabinets, edge compute racks, network closets, lab benches running high-current test equipment, and industrial workshops powering bench instruments requiring 250-volt feed from a standard PDU outlet.

Product Description

3ft IEC-60320 C14 to C19 Extension Power Cord 14AWG 15A/250V SJT, Black

 

The Cable Leader PW128-12XX is a heavy-duty IEC 60320 C14 to C19 power cord built to bridge a PDU C13 outlet to any C20-inlet device, serving as a controlled extension between rack power and high-current downstream equipment. One end carries a C14 male plug (MSL-106), the other a C19 female receptacle (MSL-119), connected by 14 AWG SJT three-conductor cable at 9.3 mm OD. Rated 15 amps at 250 volts at the system level; cable rated 300 V / 105°C.

 

The IEC C14 male plug follows the IEC 60320 standard and is the matching connector for any C13 outlet on a rack-mount PDU, UPS bypass receptacle, or in-rack power strip. Inserting the plug establishes the source-side connection, with molded PVC overmold preventing strain on the conductor terminations. The plug carries the standard "15A 250V" face marking, confirming the electrical rating at the interface and capping the assembly inside the C14 specification ceiling.

 

The IEC C19 female receptacle accepts any device with a C20 inlet — the high-current cousin of the more common C14. C20 inlets appear on enterprise rack servers, blade chassis, core and aggregation network switches, KVM-over-IP appliances, and UPS bypass cables. The C19 receptacle is rated 16 amps in the IEC spec, but the system stays constrained to 15 amps by the C14 source plug — the most common misconception, addressed in the FAQ below.

 

UL Listed under file E210037 for both molded connectors and E204978 for the SJT cable, with cUL, CSA, and RoHS compliance. The 14 AWG SJT jacket is rated VW-1 (UL) / FT2 (CSA) self-extinguishing at 105°C and 300 volts, exceeding C14-C19 interface demands by a wide margin. The jacket is permanently marked with UL file number, AWG, voltage, and flame rating, so engineers and procurement auditors can verify against site code at a glance.

 

Typical deployments cluster around four scenarios: rack-mount server installations bridging a 0U/1U PDU C13 outlet to a C20-inlet server or blade chassis (most common); UPS installations between a bypass C13 outlet and a downstream high-current server; edge compute and network closet feeds to core and aggregation network switches with C20 inlets; and laboratory or industrial workshop benches powering 250-volt instruments from a standard PDU outlet.

The black jacket provides a professional appearance and suits standard data center and enterprise rack deployments.

 

Compatible with 0U/1U basic, metered, and switched rack PDUs carrying IEC C13 outlets, rack enclosure power strips, and UPS bypass receptacles, plus any equipment fitted with an IEC C20 inlet. The PW128-12XX family is available in multiple standard rack-jumper lengths; this 3ft variant suits mid-cabinet runs and adjacent-rack connections. Black is the standard jacket color; custom colors can be quoted for installations using color-coded UPS-vs-grid feed identification.

 

All third-party trademarks are the property of their respective owners. Cable Leader is not affiliated with, endorsed by, or sponsored by any of them.

 

 

Power Cord Comparison: C14 to C19 vs Closest Alternatives

Four IEC and NEMA power cord configurations are commonly cross-shopped against a C14 to C19 power cord. The differences are not just connector shapes — they change the source you can plug into, the load you can power, and the amperage ceiling of the whole assembly. The table below compares all four side by side so the right configuration is clear before purchase.

AttributeC14 to C19 Power CordC14 to C13 Power CordC19 to C20 Power CordNEMA 5-15P to C19 Power Cord
Source (Plug)IEC 60320 C14 male plug (3-pin grounded)IEC 60320 C14 male plug (3-pin grounded)IEC 60320 C19 male plug (3-pin high-current)NEMA 5-15P standard 120 V household plug (2 flat blades + ground)
Load (Receptacle)IEC 60320 C19 female receptacle (mates with C20 inlet)IEC 60320 C13 female receptacle (mates with C14 inlet)IEC 60320 C20 male plug (mates with C19 receptacle on PDU)IEC 60320 C19 female receptacle (mates with C20 inlet)
System Amperage Ceiling15 A — constrained by C14 source plug, even though C19 is spec’d 16 A in IEC10 A (typical IT cord) or 15 A (14 AWG heavy-duty variant); constrained by C14/C13 spec16 A — both C19 and C20 are 16 A IEC spec, full high-current path15 A — constrained by NEMA 5-15 plug spec, even though C19 is 16 A
System Voltage250 V (international and North American 208 V/240 V rack feeds)250 V (international); 125 V on North American 120 V circuits250 V (international and North American 208 V/240 V)125 V — North American 120 V household circuits only
Typical Conductor14 AWG SJT 3C (heavy-duty), VW-1 / FT2 flame, 105°C, 300 V cable rating18 AWG SVT 3C (standard) or 14 AWG SJT 3C (heavy-duty variants)14 AWG SJT 3C (heavy-duty), occasionally 12 AWG for 20 A variants14 AWG SJT 3C (heavy-duty), VW-1 / FT2 flame rated
Plugs IntoPDU C13 outlets, UPS C13 bypass receptacles, in-rack power stripsPDU C13 outlets, UPS C13 bypass receptacles, in-rack power stripsHigh-current PDU C19 outlets (less common, found on enterprise rack PDUs only)Any standard North American 120 V wall outlet (no PDU required)
Powers Equipment WithC20 inlet (enterprise rack servers, blade chassis, large network switches, KVM-over-IP)C14 inlet (standard 1U servers, desktop PCs, monitors, smaller network switches)C20 inlet (same enterprise rack equipment as C14-to-C19, but with full 16 A headroom)C20 inlet (same enterprise rack equipment, but powered from 120 V wall outlet at 15 A)
Best ForRack-mount installs where the PDU has C13 outlets and the server has a C20 inlet — the most common configuration in standard server cabinetsStandard 1U server, desktop, monitor, or network switch installs where both source PDU and load equipment use the more common C13/C14 interfaceHigh-density rack installs where the PDU has dedicated high-current C19 outlets and the load equipment draws above 15 A continuousLab benches, edge-deployment cabinets, or temporary setups where no rack PDU is available but a C20-inlet device must still be powered
Common Misconception“C19 receptacle means I get 16 A” — false. C14 source caps the assembly at 15 A.“Any C14 to C13 will work” — check AWG. 18 AWG SVT is rated 10 A; only 14 AWG SJT supports 15 A loads.“C19 to C20 is the same as C14 to C19” — false. C19-to-C20 needs a PDU with C19 outlets, which are far less common than C13 outlets.“120 V is fine for a server” — only if the server’s PSU is rated for 100–240 V universal input. Many high-current PSUs require 200 V+ feed.

Choose a C14 to C19 power cord when the rack PDU or UPS has C13 outlets and the downstream equipment has a C20 inlet — the most common configuration in standard server cabinets, accepting that the assembly is capped at 15 A by the C14 source.
Choose a C14 to C13 power cord when the load is a standard 1U server, desktop, monitor, or smaller network switch with a C14 inlet rather than a C20 inlet.
Choose a C19 to C20 power cord when the PDU has dedicated high-current C19 outlets and the load requires the full 16 A IEC ceiling that a C14 source cannot deliver.
Choose a NEMA 5-15P to C19 power cord when no rack PDU is available and the C20-inlet equipment must be powered directly from a 120 V North American wall outlet at the cost of dropping to 125 V / 15 A.

 

 

FAQ

What is the difference between a C14 to C19 power cord and a C19 to C20 power cord?

A C14 to C19 power cord plugs into a PDU C13 outlet and feeds a C20-inlet device, constrained to 15 amps by the C14 source plug. A C19 to C20 power cord plugs into a higher-current PDU C19 outlet and feeds the same C20-inlet device, supporting the full 16-amp C19/C20 specification. Choose based on whether the upstream PDU outlet is a C13 (lower-current, more common) or C19 (high-current, less common).

 

Will an IEC C14 to C19 power cord work with my server's C20 inlet?

Yes — the C19 receptacle on this cord is the matched mating connector for any IEC 60320 C20 inlet found on enterprise servers, blade chassis, network switches, and KVM-over-IP appliances. Compatible C20-inlet devices include 1U and 2U enterprise rack servers, blade chassis, core and aggregation network switches, and similar high-current rack equipment. The C19 receptacle locks against accidental disengagement during routine cable management.

 

Can a 14 AWG C14 to C19 cord carry 16 amps because the C19 receptacle is rated for it?

No — the system is constrained to 15 amps by the C14 plug on the source side, even though the C19 receptacle is independently specified for 16 amps in the IEC standard. The C14 plug carries a maximum 15A UL rating at 250 volts, and the 14 AWG copper cable is sized to that ceiling. If a load requires the full 16-amp C20 inlet rating, use a C20-source cord (C19-to-C20 or NEMA L6-20P-to-C19) instead.

 

How do I connect a C14 to C19 power cord between a rack PDU and a server?

Plug the C14 male end into any IEC C13 outlet on the rack PDU or UPS bypass receptacle, then plug the C19 female end onto the C20 inlet on the server, blade chassis, or network equipment. Both interfaces are friction-fit (non-locking) IEC connectors; ensure the cord is routed without tension at either end and secured to the rack cable manager to prevent accidental disengagement during routine PDU work.

 

Which C14 to C19 power cord length is best for rack-mount equipment?

For most 1U or 2U rack servers with a top-mounted 0U PDU, a 3ft cord routes cleanly with adequate slack for cable management; 1 ft to 3 ft cords suit dense in-cabinet jumper runs where the PDU is adjacent to the server; 10 ft to 15 ft cords cover adjacent-rack feeds or installations where the C20-inlet equipment sits in a different cabinet from the C13-outlet PDU. Match the length to the actual cable run plus 10–15% slack for service loops.

Technical Specifications

Name
3ft IEC-60320 C14 to C19 Extension Power Cord 14AWG 15A/250V SJT, Black
SKU
PW128-1203
Color
Black
Gender
Male to Female
Connector
IEC320 C14 (Male) to IEC320 C19 (Female)
Condition
New
RoHS Compliant
Yes
Country of Manufacture
Vietnam
Specification
  • Manufacturer: Cable Leader
  • Model / SKU: PW128-1203
  • Connector A: IEC 60320 C14 (male plug, MSL-106, molded PVC, 3-pin grounded)
  • Connector B: IEC 60320 C19 (female receptacle, MSL-119, molded PVC, 3-blade grounded)
  • Conductor: 14 AWG x 3C (2.08 mm² stranded pure copper, non-CCA), SJT jacket, VW-1 / FT2 flame rated
  • Jacket Material: PVC, black, 9.3 mm outer diameter
  • Power Rating: 15A / 250V (system limit set by C14 plug face); cable rated 300V max
  • Temperature Rating: 105°C (UL SJT) / 105°C (CSA SJT)
  • Wiring Configuration: Black-Black (line), White-White (neutral), Green-Green (ground); one-to-one passthrough
  • Compliance: UL Listed (E210037 connectors, E204978 cable), cUL, CSA, RoHS
  • Length: 3ft (0.9 m)
  • Color: Black
  • Country of Origin: Vietnam
Features
  • IEC 60320 C14 male plug feeds power from PDU C13 outlet: The C14 plug (MSL-106, UL E210037) on one end inserts into any IEC 60320 C13 outlet on a rack PDU, UPS bypass receptacle, or in-rack power strip, providing the source side of a controlled extension between rack power infrastructure and downstream high-current equipment.
  • 14 AWG SJT cable with pure stranded copper, non-CCA conductors: The 3-conductor jacketed SJT cable runs 2.08 mm² (14 AWG) pure copper — not copper-clad aluminum — supporting 15 amps continuous at 250 volts AC under the C14 source-side limit; the SJT jacket is rated VW-1 flame retardant at 105°C with a 300-volt wire-side ceiling that exceeds the connector interface by a comfortable margin.
  • IEC 60320 C19 female receptacle accepts any C20-inlet device: The C19 receptacle (MSL-119, UL E210037) on the opposite end accepts the C20 plug found on high-current 1U and 2U rack servers, blade chassis, enterprise core and aggregation network switches, KVM-over-IP appliances, and high-capacity UPS bypass cables, letting a 15A-rated PDU outlet supply a C20-equipped load through a single locked-down assembly.
  • Versatile PDU, Server, and Data Center Applications: Serves as a heavy-duty extension between any IEC 60320 C13 outlet on 0U/1U basic, metered, and switched rack PDUs or UPS bypass receptacles and any C20-inlet equipment in server cabinets, edge compute racks, network closets, lab benches running high-current test equipment, and industrial workshops powering bench instruments requiring 250-volt feed from a standard PDU outlet.
Length
3 FT
Connector
C14 to C19
Cable Gauge
14 AWG
Power Rating
15 Amp / 250 Volt
Jacket Type
SJT