10ft IEC320 C20 to C21 Heavy Duty Power Extension Cord, 12 AWG, 20A/250V, SJT, Black

SKU: PW151-1210

In stock

loader
Volume pricing
Qty
Price
1
$16.60
2
$16.01
20
$15.42
40
$14.82
$16.60
Order today, shipped within 24 hours
Delivery method: USPS Ground Advantage® Shipping time: 2-5 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: USPS Priority Mail® Shipping time: 1-3 business days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam)
Delivery method: UPS Ground Shipping time: 1-5 Business Days depending on your location. This is not a guaranteed service. Availability: The United States (including Alaska, Hawaii, Puerto Rico and Guam) except P.O. Box
Delivery method: UPS 3 Day Select Shipping time: 3 Business Days Guarantee Service Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS 2nd Days Air Shipping time: 2 Business Days Guarantee Service Availability: All 50 U.S. states and Puerto Rico with some limitations in Alaska and Hawaii except P.O.Box
Delivery method: UPS Next Day Air Shipping time: Next Business Day Guarantee, normally by 10:30am depending on " SHIP-TO ZIP CODE" Availability: All U.S. states (including Alaska, Hawaii, Puerto Rico) except P.O.Box
Delivery method: UPS Next Day Air Saver Shipping time: Next Business Day Guarantee, normally by 3:30pm (business) and the end of the next business day (Residential) depending on "SHIP-TO ZIP CODE" Availability: All U.S. states except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Delivery method: UPS Next Day Air Early Shipping time: Next Business Day Guarantee, normally by 8:30am, depending on "SHIP-TO ZIP CODE" Availability: All 48 U.S. continguous states and Archorage, AK except Alaska, Hawaii, Puerto Rico, Guam and P.O.Box
Orders received by 2:00 PM PST are generally processed on the same business day. Orders received after this cutoff time will be processed within 24 to 48 hours. Shipping times are determined by the chosen shipping method and destination address. For details, please visit our Shipping Policy Page.
quote

Read more about Add to Quote

By adding items to your Quote Cart, you can request a personalized quote tailored to your specific needs. This is especially useful for bulk orders, as we may be able to offer you special pricing based on the quantity. Once you've added products to your Quote Cart, simply submit your request, and our team will get back to you promptly with a detailed quote. We're here to ensure you get the best value and service for your purchase!
compare

Product Features

20A/250V Heavy Duty Construction: 12 AWG (3.31 mm²) three-conductor SJT jacket carries 20 amps continuous at 250 volts, providing the headroom required by blade servers, core routers, and Layer 3 switches that draw above the 10A C13/C14 ceiling.
155°C C21 High-Temperature Receptacle: The C21 receptacle is rated to 155°C (311°F), well above the 70°C limit of standard C13 and C19 receptacles, so it stays safe inside hot-aisle racks and against C22 inlets on high-density compute and storage equipment.
12 AWG vs 14 AWG Lower Temperature Rise: 12 AWG conductors run roughly 15°F cooler than 14 AWG at 20A continuous load, reducing thermal stress on the cable, the rack environment, and the connector terminations over long duty cycles.
UL and cUL Listed for Data Center Compliance: Listed under UL file E204978 (cable) and E210037 (plug), cUL listed for Canadian deployments, and RoHS compliant; the cable jacket carries VW-1 (UL) and FT2 (cUL) flame ratings required by most data center cabling specifications.
Versatile Applications: Connects PDU C20 outlets to server, switch, router, and storage equipment with C22 inlets in 1U/2U rack environments, including blade servers, core routers, L3 switches, SAN/NAS controllers, HPC nodes, and AI training equipment in colocation, enterprise, telco, and on-premise data centers.

Product Features

20A/250V Heavy Duty Construction: 12 AWG (3.31 mm²) three-conductor SJT jacket carries 20 amps continuous at 250 volts, providing the headroom required by blade servers, core routers, and Layer 3 switches that draw above the 10A C13/C14 ceiling.
155°C C21 High-Temperature Receptacle: The C21 receptacle is rated to 155°C (311°F), well above the 70°C limit of standard C13 and C19 receptacles, so it stays safe inside hot-aisle racks and against C22 inlets on high-density compute and storage equipment.
12 AWG vs 14 AWG Lower Temperature Rise: 12 AWG conductors run roughly 15°F cooler than 14 AWG at 20A continuous load, reducing thermal stress on the cable, the rack environment, and the connector terminations over long duty cycles.
UL and cUL Listed for Data Center Compliance: Listed under UL file E204978 (cable) and E210037 (plug), cUL listed for Canadian deployments, and RoHS compliant; the cable jacket carries VW-1 (UL) and FT2 (cUL) flame ratings required by most data center cabling specifications.
Versatile Applications: Connects PDU C20 outlets to server, switch, router, and storage equipment with C22 inlets in 1U/2U rack environments, including blade servers, core routers, L3 switches, SAN/NAS controllers, HPC nodes, and AI training equipment in colocation, enterprise, telco, and on-premise data centers.

Product Description

10ft IEC320 C20 to C21 Heavy Duty Power Extension Cord, 12 AWG, 20A/250V, SJT, Black 

 

This C20 to C21 power cord is a heavy duty PDU power cord engineered for the 20A/250V circuits that power modern data center hardware. Built with 12 AWG SJT three-conductor cable, a molded IEC 60320 C20 plug, and a molded C21 receptacle rated to 155°C, it is the standard interconnect between rack PDUs and the blade servers, core routers, and high-density compute nodes that require a heavy-gauge connection. UL Listed, cUL Listed, and RoHS compliant, it meets the cabling specifications enforced in colocation, enterprise, and telco facilities across North America.


The IEC 60320 C20 plug at the PDU end is the male inlet connector defined by IEC 60320 for 20A/250V appliance couplers. It mates with the C19 outlets found on virtually every 20A rack-mount PDU shipped by Tripp Lite/Eaton, APC, CyberPower, Vertiv, and Raritan, providing the dedicated 20A circuit headroom that 10A C13/C14 cords cannot deliver. The straight-blade molded body locks securely against the PDU outlet without an adapter, and the L/N/E wiring follows the one-to-one mapping defined in IEC 60320-1.


The IEC 60320 C21 receptacle at the equipment end is the high-temperature counterpart of the more common C19. Externally it is nearly identical to a C19, with one extra chamfered notch on the keying surface, but its 155°C (311°F) thermal rating makes it the only C19-family receptacle approved against C22 inlets on equipment that runs hot. The 155°C rating applies to the connector body itself; combined with the 105°C SJT cable jacket, the assembly is rated for sustained operation in hot-aisle racks and high-density compute enclosures where ambient temperatures routinely exceed the 70°C limit of standard C19 receptacles.


This power cord is UL Listed under file E204978 (cable) and E210037 (plug), carries cUL listing for Canadian installations, and is RoHS compliant. The SJT cable jacket carries VW-1 flame rating under UL and FT2 under cUL, both required by data center electrical infrastructure specifications. The voltage marking on the jacket reads 300V to reflect cable insulation capability, while the assembly's 250V rating reflects the C20/C21 connector limit defined by IEC 60320-1, which is the binding rating for product specification purposes.


The 12 AWG conductor cross-section is the differentiator that separates this cord from generic 14 AWG and 16 AWG power cords. At 20A continuous load, 12 AWG conductors operate roughly 15°F cooler than 14 AWG conductors, reducing thermal stress on the cable, the connector terminations, and the surrounding rack airflow. This matters in hot-aisle environments where rack power distribution and bandwidth capacity push voltage requirement and equipment compatibility to their limits. Typical applications include blade server chassis, core routers, Layer 3 switches, SAN/NAS controllers, HPC nodes, AI training racks, and any 20A C22-inlet equipment in colocation, enterprise, telco, and on-premise server room environments.


Compatibility & Ordering Information: This 7 ft length fits standard 1U through 4U rack drops between adjacent or near-adjacent rack units. The cord is compatible with 20A C19-outlet rack PDUs from Tripp Lite/Eaton, APC, CyberPower, Vertiv, and Raritan, and with rack-mount IT equipment featuring C22 inlets, including Dell PowerEdge R-series, HPE ProLiant DL series, IBM Power Systems, Cisco Nexus and Catalyst high-power switches, and most blade chassis from major OEMs. Available lengths in this PW151 family include 1 ft, 2 ft, 3 ft, 4 ft, 5 ft, 6 ft, 7 ft, 8 ft, 10 ft, and 15 ft to match common rack spacing requirements. For circuits below 20A, see the PW105 family (C13 to C14, 10A); for the reverse C19 to C20 direction at the same 20A rating, see the PW150 family.

 

 

Product Comparison: C20 to C21 vs C20 to C19

Feature C20 to C21 (this product) C20 to C19 (sister product)
Connector A (PDU end) IEC 60320 C20 male plug IEC 60320 C20 male plug
Connector B (Equipment end) IEC 60320 C21 receptacle (high-temperature variant, one extra chamfered notch) IEC 60320 C19 receptacle (standard temperature, no extra notch)
Mating Equipment Inlet C22 inlet (high-power, high-temperature equipment) C20 inlet (standard 20A equipment)
Receptacle Temperature Rating 155°C / 311°F 70°C / 158°F
Power Rating 20A / 250V 20A / 250V
Conductor 12 AWG x 3C SJT 12 AWG x 3C SJT
Cable Jacket Temperature 105°C 105°C
Visual Identification C21 receptacle has one additional chamfered notch on the keying surface C19 receptacle has a smooth keying surface (no extra notch)
Typical Equipment Blade servers, core routers, L3 switches, SAN/NAS controllers, HPC and AI training nodes with C22 inlets Standard 20A rack-mount servers, switches, and storage with C20 inlets
Rack Environment Hot-aisle racks, high-density compute, environments where ambient routinely exceeds 70°C Standard server rooms, cold-aisle deployment, ambient under 70°C
Compliance UL Listed (E204978 cable, E210037 plug), cUL, RoHS, VW-1, FT2 UL Listed, cUL, RoHS, VW-1, FT2
When to Choose Equipment label specifies C22 inlet, OR rack ambient runs hot, OR sustained high-density compute load Equipment label specifies C20 inlet AND rack environment stays below 70°C

FAQ

Q1: What is the difference between a C20 and a C19 plug?

A C20 is a male plug used at the cord end, while a C19 is a female receptacle used on equipment inlets and PDU outlets — they mate together. The visual confusion is between the C19 and C21 receptacles, which look almost identical except the C21 has one additional chamfered notch on the keying surface and is rated to 155°C versus the C19's 70°C limit.

Q2: Is this C20 to C21 power cord compatible with my PDU?

Yes, if your PDU has a C19 outlet rated for 20A. The C20 plug end mates with the C19 outlets standard on 20A rack PDUs from Tripp Lite/Eaton, APC, CyberPower, Vertiv, and Raritan. The C21 end requires a C22 inlet on the equipment side, found on blade servers, core routers, and other high-temperature 20A devices.

Q3: Why does this cable use 12 AWG instead of 14 AWG?

12 AWG is required for sustained 20A operation under most data center electrical codes and runs approximately 15°F cooler than 14 AWG at the same load. 14 AWG is rated for 15A circuits; selecting it for a 20A application reduces safety margin in hot-aisle rack environments and shortens connector lifespan over long duty cycles.

Q4: How do I connect a C20 to C21 power cord between my PDU and server?

Plug the C20 male end into a C19 outlet on the rack PDU and plug the C21 female end onto the C22 inlet on the equipment chassis. Both ends are keyed for orientation and seat with a positive feel; no tools are needed. Verify the PDU outlet is rated for 20A and confirm the equipment label specifies a C22 inlet before connecting.

Q5: Which length C20 to C21 power cord is best for my server rack?

Match the cord length to the vertical distance between the PDU outlet and the equipment inlet, plus 6 to 12 inches for service loop and bend radius. The 7 ft length suits most mid-rack drops in 42U cabinets; choose 3 to 5 ft for adjacent-U connections, 8 to 10 ft for top-of-rack PDUs feeding bottom-of-rack equipment, and 15 ft for cross-rack runs.

Technical Specifications

Name
10ft IEC320 C20 to C21 Heavy Duty Power Extension Cord, 12 AWG, 20A/250V, SJT, Black
SKU
PW151-1210
Color
Black
Gender
Male to Female
Connector
IEC320 C20 (Male) to IEC320 C21 (Female)
Condition
New
RoHS Compliant
Yes
Country of Manufacture
Vietnam
Specification

Connector A: IEC 60320 C20 (male plug, molded PVC, 3-pin straight blade)
Connector B: IEC 60320 C21 (female receptacle, molded PVC, 155°C/311°F rated)
Conductor: 12 AWG x 3C (3.31 mm² stranded copper), SJT jacket
Cable Outside Diameter: 11.0 mm
Power Rating: 20A / 250V
Cable Voltage Rating: 300V
Temperature Rating: 105°C (cable jacket), 155°C (C21 receptacle)
Jacket Material: PVC, black
Wire Mapping: L-N-E one-to-one (BLACK to L, WHITE to N, GREEN to E)
Fire Rating: VW-1 (UL), FT2 (cUL)
Compliance: UL Listed (E204978 cable, E210037 plug), cUL Listed, RoHS
Length: 7 ft (2.13 m)
Color: Black
Country of Origin: Vietnam

Features

20A/250V Heavy Duty Construction: 12 AWG (3.31 mm²) three-conductor SJT jacket carries 20 amps continuous at 250 volts, providing the headroom required by blade servers, core routers, and Layer 3 switches that draw above the 10A C13/C14 ceiling.
155°C C21 High-Temperature Receptacle: The C21 receptacle is rated to 155°C (311°F), well above the 70°C limit of standard C13 and C19 receptacles, so it stays safe inside hot-aisle racks and against C22 inlets on high-density compute and storage equipment.
12 AWG vs 14 AWG Lower Temperature Rise: 12 AWG conductors run roughly 15°F cooler than 14 AWG at 20A continuous load, reducing thermal stress on the cable, the rack environment, and the connector terminations over long duty cycles.
UL and cUL Listed for Data Center Compliance: Listed under UL file E204978 (cable) and E210037 (plug), cUL listed for Canadian deployments, and RoHS compliant; the cable jacket carries VW-1 (UL) and FT2 (cUL) flame ratings required by most data center cabling specifications.
Versatile Applications: Connects PDU C20 outlets to server, switch, router, and storage equipment with C22 inlets in 1U/2U rack environments, including blade servers, core routers, L3 switches, SAN/NAS controllers, HPC nodes, and AI training equipment in colocation, enterprise, telco, and on-premise data centers.

Length
10 FT
Connector
C20 to C21
Cable Gauge
12 AWG
Power Rating
20 Amp / 250 Volt
Jacket Type
SJT